First, in order to prevent the risk of fire or explosion, the use of diesel or kerosene. Do not use gasoline, naphtha, paint thinner, alcohol, or other highly flammable fuels.
 
Second, the refueling
 
Refueling must be very familiar with the relevant provisions of the manufacturer's instructions and hot-air blowers security plus fuel.
 
1, can only use the hot air blower the specified diesel or kerosene.
 
The all flame lights are off, and the hot air blower cooling to add fuel.
 
When refueling, tubing and tubing connections you want to check whether there is a leak. Fengji before running any leaks must be repaired.
 
4, hot air blower building near the amount of fuel reserves must not exceed the amount of fuel used for the hot air blower the day, a lot of fuel reserves must be placed outside the building.
 
5 places with hot air blower to keep possession of all fuel, flamethrowers, welding equipment, and similar sources of ignition at least 1 meter away (except for fuel and hot air blower memory)
 
6, fuel storage should be limited to prevent fuel penetration or in low-lying areas are not lit area.
 
Fuel storage and official regulations must be consistent.
 
Third, where gasoline, paint thinner or other highly flammable gas Do not use a hot air blower.
 
When using hot air blower to be used in accordance with the instructions of the operation.
 
Fourth, when placed tarpaulins, canvas and similar materials near hot air blower, hot air blower should be placed in a distance away and the safety of these materials. The recommended minimum safe distance is 500 cm.
 
Further suggested that these materials are best flame retardancy. These materials should be securely fixed to prevent them from being ignited, or because of the action of the wind which interfere with the running of the hot air blower.
 
Fifth, use hot air blower in a well-ventilated place. Before using the hot air blower, ventilation openings of at least 2.8 square meters per 30kw (100,000 Btu / Hr).
 
6, where there is no flammable gas or high content of dust in use Fengji.
 
Seven, only the voltage and frequency specified on the nameplate. To maintain the stability of the voltage
 
Eight, only use with grounded plug.
 
Nine to maintain the minimum safe distance from flammable materials:
 
Exports: 250 cm
 
The sides, top and the rear side: 125 cm
 
X. If hot air blower with waste heat or running the hot air blower placed in a flat and level, otherwise fire may occur.
 
11 when moving or storing hot air blower to keep the hot air blower in a horizontal position, otherwise the fuel will overflow.
 
Children and animals should be kept away from the hot air blower.
 
12, hot air blower machine when not in use to pull the plug.
 
XIII, and used together with the temperature regulator, hot air may be activated at any time.
 
XIV should not use hot air blower in living or sleeping area.
 
XV should not block the air intake of the hot air blower (behind) the mouth and outlet (front).
 
XVI not to move, touch, refueling or maintenance of a fever, hot air blower is running or connected to the power supply.
 
17, not connected to a front or rear portion of the Fengji pipeline.
 
Clogging filters and nozzles
 
In cold weather, add non-toxic antifreeze to the fuel.
 
NOTE: use only diesel oil container, to ensure that the storage container is clean. Foreign matter such as rust, dirt or water will cause the flame control system to turn off the hot air blower. A foreign body requires regular cleaning of the fuel system